Little overlap of clock drift corrected data corrected.
Version 2.0.0 (Release ID: 60)
What's new?
Automatic clock drift correction for PPG, ACC and ECG data for better data precision during long recordings
New data files are now created depending on byte size, recording length and if the software version of the sensor / Gateway changes. Previously a new data file was created for each day.
Polar H10 accelleration data is now also recorded.
c-med° alpha contact thermometer data is also recorded in addition to the default infrared thermometer data.
Bugs fixed
Improved stability
Version 1.6.3 (Release ID: 53)
What's new?
It is now possible to stop an ongoing recording by sending a trigger of 0 seconds (via webinterface or via API).
An ongoing recording is continued if the Gateway experiences any issues or is rebooted during the recording.
Internal improvements.
Bugs fixed
In some occasions the green LED was blinking but the Gateway was not recording any data.
Version 1.5.1 (Release ID: 44)
Bugs fixed:
Some minor bugs fixed
What's new?
Internal changes
Version 1.4.3 (Release ID: 37)
Bugs fixed:
date_time_end of a data file corrected (timezone issue).
Netto-duration of a data file (duration without recording gaps) corrected.
A bug that could make the Gateway crash unexpectedly.
What's new?
Sensor errors are now reported to the server and displayed in different places of the web interface (e.g. if the PPG Signal is too low due to a defect):
The serial number of the sensor in the dash view will turn red (you may click on it to go directly to the sensor's detailed view).
In the sensor' detailed view, all found errors for this sensor are listed.
In the device overview, all devices with errors are marked with a red indicator.
Please note that in some occasions the sensor may still be functioning correctly when the error is reported but it might be a loose contact in an initial stage. In that case please have an eye on the sensor if its condition is worsening.
Server: “HELP” link in the navigation bar now leads to public wiki page.
Version 1.4.2 (Release ID: 36)
Bugs fixed:
Data upload bug of Gateway. If connected, the Gateway will upload all data previously available - independent of the currently assigned person.
Restarting loop of Gateway.
What's new?
Supported sensor devices
c-med° alpha.
Supported reference devices
Polar H10 chest strap (ECG Signal).
Data recording
Live data (feature on request). Known Issue: Sometimes no data is sent, especially when recording two sensors simultaneously.
Acceleration data. Please note: Sometimes acceleration data is sent patchy and time-delayed, causing a shift between PPG and ACC data especially during long recordings. Newest sensor firmware required (°Two 3.0.0, c-med° alpha upcoming).
Configuration
Enable WiFi for the Gateway. Technical Guide: here.
Modified advertising packets. More information available under: Select Device > advertising info.
power_behaviour
Bluetooth_behaviour
Special Notes
The c-med° alpha and the °Two shall no longer be used in Standard Mode with the Gateway if the sensor firmware is higher than 2.0.2.